Published June 1989
| Version v1
Journal article
Hysteresis and dynamic attenuation of ultrasound by lead
Description
Technique, baseed on Granato-Lucket and Rogerse models, which allows to determine number of fixation weak points, as well as, to devide losses into dynamic and hysteresis ones, is suggested. Amplitude dependence of ultrasound absorption in lead with Tl and Sn impurities in superconducting state is analyzed in terms of this technique. Evaluations for atoms and for average distances between fixation weak and strong points are made
Additional details
Additional titles
- Original title (Russian)
- Гистерезисное и динамическое поглощение ультразвука в свинце
Publishing Information
- Journal Title
- Metallofizika
- Journal Volume
- 11
- Journal Issue
- 4
- Series
- Metallofizika.
- Journal Page Range
- 66-70
- ISSN
- 0368-9662
- CODEN
- MFIZA
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 22002651
- Subject category
- S36: MATERIALS SCIENCE;
- Descriptors DEI
- AMPLITUDES; ANALYTICAL SOLUTION; DISLOCATIONS; HYSTERESIS; LEAD; SUPERCONDUCTORS; THALLIUM ADDITIONS; TIN ADDITIONS; ULTRASONIC WAVES
- Descriptors DEC
- CRYSTAL DEFECTS; CRYSTAL STRUCTURE; ELEMENTS; LINE DEFECTS; METALS; SOUND WAVES