Stand-off laser-induced breakdown spectroscopy of aluminum and geochemical reference materials at pressure below 1 torr
Creators
Description
Laser-induced breakdown spectroscopy (LIBS) is an atomic emission spectroscopy that utilizes a highly irradiated pulse laser focused on the target surface to produce plasma. We obtain spectroscopic information from the microplasma and determine the chemical composition of the sample based on its elemental and molecular emission peaks. We develop a stand-off LIBS system to analyze the effect of the remote sensing of aluminum and various geochemical reference materials at pressures below 1 torr. Using a commercial 4 inch refracting telescope, our stand-off LIBS system is configured at a distance of 7.2 m from the four United States Geological Survey (USGS) geochemical samples that include granodiorite, quartz latite, shale-cody, and diabase, which are selected for planetary exploration. Prepared samples were mixed with a paraffin binder containing only hydrogen and carbon, and were pelletized for experimental convenience. The aluminum plate sample is considered as a reference prior to using the geochemical samples in order to understand the influence of a low pressure condition on the resulting LIBS signal. A Q-switched Nd:YAG laser operating at 1064 nm and pulsed at 10 Hz with 21.7 to 48.5 mJ/pulse was used to obtain signals, which showed that the geochemical samples were successfully detected by the present stand-off detection scheme. A low pressure condition generally results in a decrease of the signal intensity, while the signal to noise ratio can vary according to the samples and elements of various types. We successfully identified the signals at below 1 torr with stand-off detection by a tightly focused light detection and by using a relatively larger aperture telescope. The stand-off LIBS detection at low pressure is promising for potential detection of the minor elements at pressures below 1 torr. - Highlights: • Stand-off LIBS signals at below 1 torr are compared to those of in-situ conditions. • Vacuum condition provides easier detection of the ionized peaks with high SNR. • Geochemical samples are successfully detected at such low pressure of 10−2 torr. • Calibration curves show accuracy and provide potential for further improvement
Availability note (English)
Available from http://dx.doi.org/10.1016/j.sab.2014.06.009Additional details
Identifiers
- DOI
- 10.1016/j.sab.2014.06.009;
- PII
- S0584-8547(14)00113-X;
Publishing Information
- Journal Title
- Spectrochimica Acta. Part B, Atomic Spectroscopy
- Journal Volume
- 101
- Journal Page Range
- p. 335-341
- ISSN
- 0584-8547
- CODEN
- SAASBH
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47009078
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ACCURACY; ALUMINIUM; BREAKDOWN; CALIBRATION; CARBON; CHEMICAL COMPOSITION; DETECTION; EMISSION SPECTROSCOPY; GEOCHEMISTRY; HYDROGEN; IRRADIATION; LASER SPECTROSCOPY; LASER-PRODUCED PLASMA; MULTI-ELEMENT ANALYSIS; NEODYMIUM LASERS; QUANTITATIVE CHEMICAL ANALYSIS; QUARTZ; SIGNAL-TO-NOISE RATIO; VISIBLE RADIATION
- Descriptors DEC
- CHEMICAL ANALYSIS; CHEMISTRY; DIMENSIONLESS NUMBERS; ELECTROMAGNETIC RADIATION; ELEMENTS; LASERS; METALS; MINERALS; NONMETALS; OXIDE MINERALS; PLASMA; RADIATIONS; SOLID STATE LASERS; SPECTROSCOPY
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.