Metrological reliability of the calibration procedure for dosimeters used in mammography
- 1. Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil).SECDOS
Description
The laboratory Physikalisch-Technische Bundesanstalt, PTB - Germany established X-rays of references for calibration of dosimeters used in dosimetry in mammography, which are generated by X-ray tubes with tungsten anode and filtered with aluminum, molybdenum, rhodium silver and others. These reference radiations complement the qualities of the International Electrotechical Commission (IEC) number 61267 for calibration of dosimeters in mammography, since few calibration laboratories have an X-ray device with a molybdenum anode for dosimeter calibration. In this work, from the implantation of some reference radiations similar to those established by the PTB in the in the Dosimeter Calibration Laboratory (LCD) located at the Nuclear Technology Development Center (CDTN). The calibration procedure used in mammography was validated through calibrations of a Radcal 10X6-6m ionization chamber and a Radcal Accu-gold semiconductor dosimeter, model AGMS-M. The results indicated the metrological reliability of the procedure and evidenced the influence of the software configuration on the semiconductor dosimeter calibration coefficients. (author)
Files
54100040.pdf
Files
(500.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:83386446ca39e29fcefb354435e05a79
|
500.2 kB | Preview Download |
Additional details
Additional titles
- Original title (Portuguese)
- Confiabilidade metrológica do procedimento de calibração de dosímetros usados em mamografia
Publishing Information
- Imprint Title
- Proceedings of the 26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics
- Imprint Pagination
- 177 p.
- Journal Page Range
- 4 p.
- Report number
- INIS-BR--24586
Conference
- Title
- 26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics
- Dates
- 8-11 Jun 2022
- Place
- Fortaleza, CE (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 54100040
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; COMPUTER CODES; IONIZATION CHAMBERS; MAMMARY GLANDS; RADIATION DETECTORS; RADIATION METROLOGY; X RADIATION
- Descriptors DEC
- BODY; ELECTROMAGNETIC RADIATION; GLANDS; IONIZING RADIATIONS; MEASURING INSTRUMENTS; METROLOGY; ORGANS; RADIATION DETECTORS; RADIATIONS
Optional Information
- Notes
- Imprint:Anais do 26. Congresso brasileiro de f#Latin Small Letter I With Acute#sica m#Latin Small Letter E With Acute#dica; 9. Congresso latino-americano de f#Latin Small Letter I With Acute#sica m#Latin Small Letter E With Acute#dica