Published February 2009 | Version v1
Journal article

Iodine-125 radioactivity during production test using enriched Xenon-124 target

  • 1. Pusat Radioisotop dan Radiofarmaka - BATAN, Kawasan Puspiptek Serpong, Tangerang (Indonesia)

Description

Production tests of Iodine-125 have been carried out using enriched xenon target with 82,4% of 124Xe enrichment. The target was irradiated at irradiation chamber in S1 position of G.A. Siwabessy reactor. After irradiation for 24 hours, the irradiated xenon gas was decayed at decay pot for 7 days. The produced iodine-125 was dissolved 3 times using NaOH 0.005N. From 1st to 8th tests, the total radioactivities were 9541, 9801, 11239, 9458, 3293. 3735, 4693 and 2744 mCi. The decrease of the total radioactivity was caused by the decrease of the gas target. Radioactivity of the 1st solution depended on the volume of NaOH solution. The average percentages of the 1st solution were 65.1, 71.5 and 82.6% of the total radioactivity for 3, 4 and 5 mL of NaOH. The maximum radioactivity concentration was 3410 mCi/mL from 1st solution of the 1st production test. (author)

Additional details

Additional titles

Original title (Indonesian)
Radioaktivitas Iodium-125 pada uji produksi menggunakan target Xenon-124 diperkaya

Publishing Information

Journal Title
Jurnal Sains dan Teknologi Nuklir Indonesia
Journal Volume
X
Journal Issue
1
Journal Page Range
p. 1-9
ISSN
1411-3481

Optional Information

Notes
12 refs.; 2 tabs.; 5 figs.