Published October 1996
| Version v1
Journal article
Planning maintenance during the first outage and refuelling of Qinshan 300 MW Nuclear Power Unit
Description
To take an example in the equipment maintenance of the primary circuit and auxiliary systems, this paper sums up the first outage and refuelling planning maintenance of Qinshan 300 MW Nuclear Power Unit. It concludes the guiding principle and preparatory treatment. Some suggestions are put forward. These suggestions provide active function for improving planning maintenance and management of Qinshan Nuclear Power Plant
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 17
- Journal Issue
- 5
- Journal Page Range
- p. 403-406.
- ISSN
- 0258-0926
- CODEN
- HDGOE6
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 28026035
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- MODIFICATIONS; NUCLEAR POWER PLANTS; PRIMARY COOLANT CIRCUITS; QINSHAN REACTOR; REACTOR FUELING; REACTOR SHUTDOWN; REPAIR
- Descriptors DEC
- COOLING SYSTEMS; ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; SHUTDOWN; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS