Integrated cardio-thoracic imaging with ECG-Gated 64-slice multidetector-row CT: initial findings in 133 patients
Creators
- 1. Hospital Calmette, University Center of Lille, Department of Thoracic Imaging, LILLE cedex (France)
- 2. University of Lille, Place de Verdun, Department of Medical Statistics, LILLE cedex (France)
Description
The purpose of this study was to investigate the possibility of assessing the underlying respiratory disease as well as cardiac function during ECG-gated CT angiography of the chest with 64-slice multidetector-row CT (MDCT). One hundred thirty-three consecutive patients in sinus rhythm with known or suspected ventricular dysfunction underwent an ECG-gated CT angiographic examination of the chest without β-blockers using the following parameters: (1) collimation: 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices (Sensation 64; Siemens); rotation time: 0.33 s; pitch: 0.3; 120 kV; 200 mAs; ECG-controlled dose modulation (ECG-pulsing) and (2) 120 ml of a 35% contrast agent. Data were reconstructed: (1) to evaluate the underlying respiratory disease (1-mm thick lung and mediastinal scans reconstructed at 55% of the R-R interval; i.e., ''morphologic scans'') and (2) to determine right (RVEF) and left (LVEF) ventricular ejection fractions (short-axis systolic and diastolic images; Argus software; i.e., ''functional scans''). The mean heart rate was 73 bpm (range: 42-120) and the mean scan time was 18.11±2.67 s (range: 10-27). A total of 123 examinations (92%) had both lung and mediastinal images rated as diagnostic scans, whereas 10 examinations (8%) had non-diagnostic images altered by the presence of respiratory-motion artifacts (n=4) or cyclic artifacts related to the use of a pitch value of 0.3 in patients with a very low heart rate during data acquisition (n=6). Assessment of right and left ventricular function was achievable in 124 patients (93%, 95% CI: 88-97%). For these 124 examinations, the mean RVEF was 46.10% (±9.5; range: 20-72) and the mean LVEF was 58.23% (±10.88; range: 20-83). In the remaining nine patients, an imprecise segmentation of the right and left ventricular cavities was considered as a limiting factor for precise calculation of end-systolic and end-diastolic ventricular volumes. The mean (±SD) DLP value of the examinations was 279.86 (±117.50) mGy.cm. Assessment of underlying respiratory disease and cardiac function from the same data set was achievable in 92% of the patients with ECG-gated 64-slice MDCT. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-006-0157-xAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 16
- Journal Issue
- 9
- Journal Page Range
- p. 1973-1981
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 37102002
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARDIOVASCULAR SYSTEM; CHEST; COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; IMAGE PROCESSING
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; PROCESSING; TOMOGRAPHY