Published October 2017 | Version v1
Journal article

Numerical Study of Thermo-Fluid Features of Electrically Conducting Fluids in Tube Bank Heat Exchangers Exposed to Uniform Magnetic Fields

  • 1. Kyungpook Nat'l Univ., Daegu (Korea, Republic of)

Description

When an electrically conducting fluid flows through a staggered tube bank, the heat transfer and fluid flow features are changed by the externally introduced magnetic field. This study provides a numerical investigation of this phenomenon. Heat and fluid flows are investigated for unsteady laminar flows at Reynolds numbers of 50 and 100 with the Hartmann number gradually increasing from zero to 100. As the Hartmann number increases, and owing to the effects of the introduced magnetic field, the velocity boundary layer near the tube wall is thinned, the flow separation is delayed downstream, and the shrinkage of a recirculation zone formed near the rear side is observed. Based on these thermo-fluid deformations, the resulting changes in the local and average Nusselt number are investigated.

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
41
Journal Issue
10
Series
12 refs, 10 figs, 1 tab
Journal Page Range
p. 659-665
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
48090115
Subject category
S42: ENGINEERING;
Descriptors DEI
DEFORMATION; FLUID FLOW; HEAT; HEAT EXCHANGERS; HEAT TRANSFER; MAGNETIC FIELDS; MAGNETOHYDRODYNAMICS; NUSSELT NUMBER; TUBES
Descriptors DEC
DIMENSIONLESS NUMBERS; ENERGY; ENERGY TRANSFER; FLUID MECHANICS; HYDRODYNAMICS; MECHANICS