Neutron detection in a high gamma-ray background with EJ-301 and EJ-309 liquid scintillators

  • 1. Dipartimento di Fisica ed Astronomia dell' Università di Padova, Fisica "Galileo Galilei", Via Marzolo 8, I-35131 Padova (Italy)
  • 2. INFN Sezione di Padova, Via Marzolo 8, I-35131 Padova (Italy)

Description

Using a fast digitizer, the neutron–gamma discrimination capability of the new liquid scintillator EJ-309 is compared with that obtained using standard EJ-301. Moreover the capability of both the scintillation detectors to identify a weak neutron source in a high gamma-ray background is demonstrated. The probability of neutron detection is PD=95% at 95% confidence level for a gamma-ray background corresponding to a dose rate of 100 μSv/h.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2012.06.047

Additional details

Identifiers

DOI
10.1016/j.nima.2012.06.047;
PII
S0168-9002(12)00713-9;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
690
Journal Issue
Complete
Journal Page Range
p. 96-101
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.