Effective pulsed-repetitive vircator with double anode grid

Description

In this paper we present investigation results of a vircator characteristics with a double anode grid operating in pulsed-repetitive regime. Electrons were emitted with a plain graphite cathode and injected to a parabolic drift chamber of the vircator through the anode, made of tungsten wire. Experimentally it was shown that use of the anode on the form of double grid provides significant increase of the generated microwave radiation in comparison with a traditional single-grid variant

Abstract (Russian)

Исследуются характеристики виркатора с двойной анодной сеткой, работающего в импульсно-периодическом режиме. Электроны эмитируются из плоского графитового катода и инжектируются в параболическую дрейфовую камеру виркатора через анод из вольфрамовой проволоки. Экспериментально показано, что использование анода в форме двойной сетки существенно увеличивает генерируемую микроволновую мощность по сравнению с традиционными вариантами
Part of:
15th International conference on high-power particle beams. BEAMS'2004. Proceedings

Additional details

Publishing Information

Publisher
D.V. Efremov Scientific Research Inst. of Electrophysical Apparatus
Imprint Place
Saint-Petersburg (Russian Federation)
ISBN
5-87911-088-5
Imprint Title
15th International conference on high-power particle beams. BEAMS'2004. Proceedings
Imprint Pagination
922 p.
Journal Page Range
p. 544-547

Conference

Title
15. International conference on high-power particle beams. BEAMS'2004
Dates
18-23 Jul 2004
Place
Saint-Petersburg (Russian Federation)

INIS

Country of Publication
Russian Federation
Country of Input or Organization
Russian Federation
INIS RN
37073395
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANODES; COMPARATIVE EVALUATIONS; EFFICIENCY; GRIDS; MICROWAVE RADIATION; OSCILLATORS; POWER DENSITY; PULSES
Descriptors DEC
ELECTRODES; ELECTROMAGNETIC RADIATION; ELECTRONIC EQUIPMENT; EQUIPMENT; EVALUATION; RADIATIONS

Optional Information

Notes