Published February 15, 2019 | Version v1
Journal article

Diagnostic accuracy of F-18 FDG PET/CT for characterization of colorectal focal FDG uptake: a systematic review and meta-analysis

  • 1. Pusan National University Yangsan Hospital, Department of Surgery (Korea, Republic of)
  • 2. Pusan National University Yangsan Hospital, BioMedical Research Institute for Convergence of Biomedical Science and Technology (Korea, Republic of)

Description

Introduction

We aimed to explore the role of the diagnostic accuracy of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for characterization of incidental colorectal focal FDG uptake through a systematic review and meta-analysis.

Methods

The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR−), and constructed summary receiver operating characteristic curves.

Results

Across 8 studies (1451 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.87 (95% CI 0.82–0.90) without heterogeneity (χ2 = 10.84, p = 0.37) and a pooled specificity of 0.83 (95% CI 0.76–0.89) with heterogeneity (χ2 = 130.1, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 5.2 (95% CI 3.6–7.4) and negative likelihood ratio (LR−) of 0.16 (95% CI 0.12–0.22). The pooled DOR was 32 (95% CI 20–51).

Conclusion

F-18 FDG PET/CT demonstrated good sensitivity and specificity for characterization of incidental colorectal focal FDG uptake. At present, the literature regarding the use of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake.

Additional details

Identifiers

Publishing Information

Journal Title
Abdominal Radiology (Online)
Journal Volume
44
Journal Issue
2
Journal Page Range
p. 456-463
ISSN
2366-0058

Optional Information

Copyright
Copyright (c) 2019 Springer Science+Business Media, LLC, part of Springer Nature