Published June 1992
| Version v1
Report
Restricted
Locked modes and magnetic field errors in MST
Description
In the MST reversed field pinch magnetic oscillations become stationary (locked) in the lab frame as a result of a process involving interactions between the modes, sawteeth, and field errors. Several helical modes become phase locked to each other to form a rotating localized disturbance, the disturbance locks to an impulsive field error generated at a sawtooth crash, the error fields grow monotonically after locking (perhaps due to an unstable interaction between the modes and field error), and over the tens of milliseconds of growth confinement degrades and the discharge eventually terminates. Field error control has been partially successful in eliminating locking
Availability note (English)
MF available from INIS under the Report Number; OSTI as DE92015379; NTIS; INIS; US Govt. Printing Office Dep.
Files
Additional details
Publishing Information
- Imprint Pagination
- 24 p.
- Report number
- DOE/ER/53198--197
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 23073447
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ERRORS; MAGNETIC FIELDS; MODE LOCKING; OSCILLATION MODES; REVERSE-FIELD PINCH; SAWTOOTH OSCILLATIONS; TEARING INSTABILITY
- Descriptors DEC
- INSTABILITY; OSCILLATIONS; PINCH EFFECT; PLASMA INSTABILITY; PLASMA MACROINSTABILITIES
Optional Information
- Contract/Grant/Project number
- Contract FG02-85ER53198
- Funding organization
- USDOE, Washington, DC (United States).