Published 1979
| Version v1
Report
Open
Tensimeter for multiwire chamber wires
Description
Principle of operation and flowsheet of a device for measuring the mechanical tension in wires of multiwire chambers with the 1-5 percent accuracy is described. For measurements only one electrical contact with wire outlets is required. Tension determining goes automatically, manual mode of operation is also provided for. The principle of operation is based on the excitation and detection of mechanical oscillations of wires by the electronic way and by determining a resonance
Availability note (English)
MF available from INIS under the Report Number.Files
10495147.pdf
Files
(196.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:38e75a3b2748926a749aad9e9ce18fbb
|
196.3 kB | Preview Download |
System files
(28.9 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Измерител' натяжений нитей многопроволочных камер
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- JINR--13-12244
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 10495147
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCURACY; FLOWSHEETS; MECHANICAL VIBRATIONS; MULTIWIRE IONIZATION CHAMBERS; MULTIWIRE PROPORTIONAL CHAMBER; RESONANCE; SPECIFICATIONS; TENSILE PROPERTIES; WIRES
- Descriptors DEC
- DIAGRAMS; INFORMATION; IONIZATION CHAMBERS; MEASURING INSTRUMENTS; MECHANICAL PROPERTIES; PROPORTIONAL COUNTERS; RADIATION DETECTORS
Optional Information
- Notes
- 4 refs.; 4 figs.; submitted to the journal Prib. Tekh. Ehksp.