Published October 1985
| Version v1
Journal article
Magnet power supply control, of the NSLS VUV and X-ray storage rings, transfer lines
- 1. Brookhaven National Laboratory, Upton, NY
Description
The transfer lines for NSLS VUV and X-ray storage rings have been split. New power supplies have been incorporated with existing ones. The existing microprocessor system has been upgraded in order to control the additional functions. This system expands the input/output port of the microprocessor to an addressable serial/parallel link to each magnet power supply. The implementation of this system will be discussed
Additional details
Publishing Information
- Journal Title
- IEEE Trans. Nucl. Sci.
- Journal Volume
- NS-32
- Journal Issue
- 5
- Series
- IEEE Trans. Nucl. Sci.
- Journal Page Range
- 2020-2022
- ISSN
- 0018-9499
- CODEN
- IETNA
Conference
- Title
- Particle accelerator conference.
- Dates
- 13-16 May 1985.
- Place
- Vancouver (Canada).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17051452
- Subject category
- S43: PARTICLE ACCELERATORS; S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- MAGNETS; MICROPROCESSORS; NSLS; ON-LINE CONTROL SYSTEMS; POWER SUPPLIES; STORAGE RINGS
- Descriptors DEC
- CONTROL SYSTEMS; ELECTRONIC CIRCUITS; ELECTRONIC EQUIPMENT; EQUIPMENT; MICROELECTRONIC CIRCUITS; ON-LINE SYSTEMS; RADIATION SOURCES; SYNCHROTRON RADIATION SOURCES
Optional Information
- Secondary number(s)
- CONF-850504--.