Residual stress measurement and analysis of dissimilar metal surge line nozzle

  • 1. Mitsubishi Heavy Industries, Ltd., Takasago, Hyogo (Japan)
  • 2. Osaka Univ., Ibaraki, Osaka (Japan)
  • 3. Japan Nuclear Energy Safety Organization, Tokyo (Japan)

Description

The stress distribution through the center-line of the mock-up weldment was measured using the inherent strain method. And FE analysis was performed to calculate the stress distributions for each fabrication process. Comparing with measurement results, the validity of the FE analysis was confirmed. (author)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
Proceedings of 2009 international congress on advances in nuclear power plants

Additional details

Publishing Information

Imprint Title
Proceedings of 2009 international congress on advances in nuclear power plants
Imprint Pagination
[2572 p.]
Journal Page Range
[1 p.]
Report number
INIS-JP--123

Conference

Title
2009 international congress on advances in nuclear power plants
Acronym
ICAPP2009
Dates
10-14 May 2009
Place
Tokyo (Japan)

Optional Information

Notes
Available as CD-ROM Data in PDF format, Folder Name: FinalPaper, Paper ID: 9486.pdf; 2 refs., 2 figs.