Effect of beam divergence on the accuracy of experimental-analytical determination of thickness of layer analysed in X-ray radiographic testing of objects by sliding beam
- 1. Kujbyshevskij Aviatsionnyj Inst. (USSR)
Description
The effect of beam divergence ω on the accuracy of determination of thickness t of material layer participating in creating the deffraction image is analyzed. The error in determining the Δt/t thickness related to ω is proportional to ω/α (α-beam slope angle to sample plane). At α=PHIsub(m)+ω/2 (PHOsub(m)-angle of total external reflection) Δt/t >100%. When α 100%. When αTHETA (THETA-slide angle), Δt/t <= 5%. At α=90 deg Δt/t < 1%. Taking armko-iron as an example shown is the possibility of ω selection ensuring the determination of absolute value t in case of readiography of the ob ect with diffractometers by sliding beam with an error not exceeding 10%. The results obtained are required for nondestructive X-ray in layers analysis of substances
Additional details
Additional titles
- Original title (Russian)
- Влияние расходимости лучей на точност' экспериментально-аналитического определения толщины анализируемого слоя при рентгенографировании обьектов скользящим пучком
Publishing Information
- Journal Title
- Zavod. Lab.
- Journal Volume
- 51
- Journal Issue
- 1
- Series
- Zavod. Lab.
- Journal Page Range
- 25-27
- ISSN
- 0321-4265
- CODEN
- ZVDLA
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- USSR
- INIS RN
- 17016984
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- ACCURACY; BEAM OPTICS; IRON BASE ALLOYS; LAYERS; OPTIMIZATION; THICKNESS; X-RAY RADIOGRAPHY
- Descriptors DEC
- ALLOYS; DIMENSIONS; IRON ALLOYS
Optional Information
- Notes
- For English translation see the journal Industrial Laboratory (USA).