Published January 2002 | Version v1
Journal article

A new absolute method for the standardization of radionuclides emitting low-energy radiation

Description

Microcalorimeters (or bolometers) operated at temperatures below 100 mK allow individual counting of photons and electrons with a very low energy detection threshold. The physics is based on the pulse temperature increase of the target (or absorber) of the detector due to the complete absorption of both electrons and photons. Since this target can be constructed with a perfect 4-π geometry, a bolometer offers potentially a new method for absolute activity measurements of radionuclides emitting low-energy radiation. In this paper we present our first results of a feasibility study of activity standardization of a 55Fe solution with a prototype 4-π bolometer

Additional details

Identifiers

PII
S0969804301001956;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
56
Journal Issue
1-2
Journal Page Range
p. 245-251
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Copyright
Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.