Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

Description

Past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and molecular emission are not spatially homogenous throughout the source, but rather conform to specific zones within the discharge. Exploiting this inhomogeneity can lead to improved analytical performance if emission is collected only from regions of the discharge where analyte species emit strongly and background emission (from continuum, elemental and/or molecular sources) is lower. Effects of this form of spatial discrimination on the analytical performance of SCGD optical emission spectrometry (OES) have been investigated with an imaging spectrograph for fourteen atomic lines, with emphasis on detection limits and precision. Vertical profiles of the emission intensity, signal-to-background ratio, and signal-to-noise ratio were collected and used to determine the optimal region to view the SCGD on a per-element basis. With optimized spatial filtering, detection limits ranged from 0.09–360 ppb, a 1.4–13.6 fold improvement over those obtained when emission is collected from the full vertical profile (1.1–840 ppb), with a 4.2-fold average improvement. Precision was found to be unaffected by spatial filtering, ranging from 0.5–2.6% relative standard deviation (RSD) for all elements investigated, closely comparable to the 0.4–2.4% RSD observed when no spatial filtering is used. Spatial profiles also appear useful for identifying optimal line pairs for internal standardization and for flagging the presence of matrix interferences in SCGD-OES. - Highlights: • Spatial discrimination was used to enhance detection limits in SCGD-OES. • Optimized spatial filtering yields detection limits improved by a factor of 1.4–13.6. • Spatial emission profiles are useful for identification of line pairs for internal standardization. • Matrix interferences can be flagged through use of spatial profiles.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.sab.2016.10.004

Additional details

Identifiers

DOI
10.1016/j.sab.2016.10.004;
PII
S0584-8547(16)30253-1;

Publishing Information

Journal Title
Spectrochimica Acta. Part B, Atomic Spectroscopy
Journal Volume
125
Journal Page Range
p. 168-176
ISSN
0584-8547
CODEN
SAASBH

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49102989
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CATHODES; EMISSION SPECTROSCOPY; GLOW DISCHARGES; SIGNAL-TO-NOISE RATIO
Descriptors DEC
DIMENSIONLESS NUMBERS; ELECTRIC DISCHARGES; ELECTRODES; SPECTROSCOPY