Published 1977 | Version v1
Book

Neutron and gamma-ray flux-to-dose rate factors

Creators

Description

Intended for use by shield designers to calculate whole-body dose rates to radiation workers and the general public, this standard presents flux-to-dose rate conversion factors for neutrons (1.5x10-8 to 20 MeV) and gamma rays (0.01 to 15 MeV). Definitions used are based on ANS-9-1976(N1.1-1976)

Additional details

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (USA)
Imprint Pagination
v p.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
15064092
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Standard or Specification
Descriptors DEI
BIOLOGICAL SHIELDS; DOSE RATES; GAMMA RADIATION; NEUTRON FLUX; RADIATION PROTECTION; SPECIFICATIONS
Descriptors DEC
ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; RADIATION FLUX; RADIATIONS; SHIELDS

Optional Information

Secondary number(s)
ANSI/ANS--6.1.1-1977.