Published January 1, 2000 | Version v1
Report Open

Remote Methodology used at B Plant Hanford to Map High Radiation and Contamination Fields and Document Remaining Hazards

Description

A remote radiation mapping system using the Gammacam(trademark) (AIL Systems Inc. Trademark) with real-time response was used in deactivating the B Plant at Hanford to produce digitized images showing actual radiation fields and dose rates. Deployment of this technology has significantly reduced labor requirements, decreased personnel exposure, and increased the accuracy of the measurements. Personnel entries into the high radiation/contamination areas was minimized for a dose savings of 30 Rem (.3 Seivert) and a cost savings of $640K. In addition, the data gathered was utilized along with historical information to estimate the amount of remaining hazardous waste in the process cells. The B Plant facility is a canyon facility containing 40 process cells which were used to separate cesium and strontium from high level waste. The cells and vessels are contaminated with chemicals used in the separation and purification processes. Most of the contaminants have been removed but the residual contamination from spills in the cells and heels in the tanks contribute to the localized high radioactivity. The Gammacam(trademark) system consists of a high density terbium-activated scintillating glass detector coupled with a digitized video camera. Composite images generated by the system are presented in pseudo color over a black and white image. Exposure times can be set from 10 milliseconds to 1 hour depending on the field intensity. This information coupled with process knowledge is then used to document the hazardous waste remaining in each cell. Additional uses for this radiation mapping system would be in support of facilities stabilization and deactivation activities at Hanford or other DOE sites. The system is currently scheduled for installation and mapping of the U Plant in 1999. This system is unique due to its portability and its suitability for use in high dose rate areas

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00801106; PURL: https://www.osti.gov/servlets/purl/801106-7ritxp/webviewable/

Files

34016153.pdf

Files (423.2 kB)

Name Size Download all
md5:c809fb42c3e89685967c1a4a9aef2707
423.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
11 p.
Report number
HNF--3938-FP

Optional Information

Contract/Grant/Project number
AC06-96RL13200
Funding organization
ENVIRONMENTAL MANAGEMENT (United States)