The method of anode wire incident angle calculation of the first muon station (ME1/1) of the compact muon solenoid set-up (CVS)
Description
For achievement of a high spatial resolution of the Cathode Strip Chamber (CSC) in crossed electric and magnetic fields it's necessary to know the effective Lorentz angle. A new method has been proposed for the effective Lorentz angle measurement without using special detectors. The experimental results have been used for CSC anode wire incident angle measurement for different gas mixtures and a magnetic field similar to that of Compact Muon Solenoid (CMS) set-up. The magnetic field components influence on the spatial resolution has been shown
Files
33009043.pdf
Files
(289.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:788b227a12d617fae07752f462713957
|
289.3 kB | Preview Download |
System files
(28.7 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Методика вычисления угла наклона анодной проволоки первой мюонной станции (ME1/1) установки компактный мюонный соленоид (CMS)
Publishing Information
- Imprint Title
- Particles and nuclei, letters
- Imprint Pagination
- 128 p.
- Journal Page Range
- p. 82-92
- Report number
- JINR--4-107-2001
INIS
- Country of Publication
- Joint Institute for Nuclear Research (JINR)
- Country of Input or Organization
- Joint Institute for Nuclear Research (JINR)
- INIS RN
- 33009043
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ANODES; CATHODES; ELECTRIC FIELDS; MAGNETIC FIELDS; MULTIWIRE PROPORTIONAL CHAMBERS; READOUT SYSTEMS; SPATIAL RESOLUTION
- Descriptors DEC
- ELECTRODES; MEASURING INSTRUMENTS; PROPORTIONAL COUNTERS; RADIATION DETECTORS; RESOLUTION
Optional Information
- Notes
- 7 refs., 14 figs. Imprint:Pis'ma v EhChAYa