Published January 1976
| Version v1
Journal article
Coulometric titration of niobium in EDTA complexing solution
Description
Constant current coulometry of Nb in EDTA was studied employing both potentiometric and amperometric end-point techniques. The titrations were based on the oxidation of Nb(IV)-EDTA with electrogenerated Fe(III) at a graphite anode. The rate of disproportionation of Nb(IV)-EDTA was found to be slow enough not to effect the accuracy sought for the titration. The coulometric titration of Nb in EDTA was found to be more accurate than in 1F sulfuric acid. The mean error in the titrations of 4.76 to 19.65 of Nb in a volume of about 100 ml of 0.02 to 0.04F EDTA was 0.13%. It was found that Ta may be tolerated to a ratio of 1:4, Ta:Nb, in a solution containing 13 mg of Nb. (author)
Additional details
Publishing Information
- Journal Title
- J. Indian Chem. Soc.
- Journal Volume
- 53
- Journal Issue
- 1
- Series
- J. Indian Chem. Soc.
- Journal Page Range
- 56-58
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 7259512
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ACCURACY; EDTA; ERRORS; INTERFERING ELEMENTS; NIOBIUM; QUANTITATIVE CHEMICAL ANALYSIS; TANTALUM; VOLTAMETRY
- Descriptors DEC
- AMINO ACIDS; CARBOXYLIC ACIDS; CHELATING AGENTS; CHEMICAL ANALYSIS; ELEMENTS; METALS; ORGANIC ACIDS; ORGANIC COMPOUNDS; TRANSITION ELEMENTS
Optional Information
- Notes
- 9 refs.