Description

Work was carried out to determine the appropriate thickness of concrete block that would be sufficient to protect the radiation worker and the public from X-rays for medical purpose. The results obtained from four X-ray machines are discussed. However, a minimum thickness of 36.0cm of concrete block was found to be sufficient to protect the two groups mentioned here.

Availability note (English)

Available from Nigeria Atomic Energy Commission, 9 Kwame Nkrumah Crescent Asokoro, P.M.B. 646 Garki Abuja (NG)