Published June 1, 2005 | Version v1
Report

Radiation in the C0 assembly hall due to muons from accidental beam loss in the Tevatron

Description

A set of calculations performed with the MARS15 code indicates a maximum radiation dose due to muons in the C0 Assembly Building (C0 AB) for a person standing on a ladder in the orbit plane of the Tevatron of 10 mrem and a maximum dose for a person standing on a C0 AB floor < 1 mrem per loss of 2.5 x 1013 protons of 1 TeV energy in the Tevatron

Availability note (English)

Available from OSTI as DE15020255; PURL: https://www.osti.gov/servlets/purl/15020255-wpdC1o/

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
FERMILAB-FN--0768-AD

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
37084020
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
FERMILAB TEVATRON; FLOORS; MUONS; PERSONNEL DOSIMETRY; PROTONS; RADIATION DOSES; RADIATIONS
Descriptors DEC
ACCELERATORS; BARYONS; CYCLIC ACCELERATORS; DOSES; DOSIMETRY; ELEMENTARY PARTICLES; FERMIONS; HADRONS; LEPTONS; NUCLEONS; SYNCHROTRONS

Optional Information

Contract/Grant/Project number
AC02-76CH03000
Funding organization
US Department of Energy (United States)