The effect of a plate axial to the flow on the liquid distribution in annular two-phase flow

  • 1. Department of Chemical Engineering, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom)

Description

The effect of a plate placed parallel to the flow direction across the diameter of a vertical tube containing annular two-phase flow has been studied experimentally. The plate has very little effect on the amount of liquid entrained as drops. A modification of an annular-flow model has been developed which correctly predicts the small changes in entrained fraction across the plate. ((orig.))

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
152
Journal Issue
1-3
Journal Page Range
p. 257-262.
ISSN
0029-5493
CODEN
NEDEAU

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
26044841
Subject category
S42: ENGINEERING;
Descriptors DEI
ANNULAR SPACE; CRITICAL HEAT FLUX; FILM BOILING; GAS FLOW; LIQUID FLOW; PLATES; SPACERS; TWO-PHASE FLOW
Descriptors DEC
BOILING; CONFIGURATION; FLUID FLOW; HEAT FLUX; PHASE TRANSFORMATIONS