Combined large field-of-view MRA and time-resolved MRA of the lower extremities: Impact of acquisition order on image quality
Creators
- 1. Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)
- 2. Department of Medical Statistics and Biomathematics, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)
Description
Purpose: Different approaches exist for hybrid MRA of the calf station. So far, the order of the acquisition of the focused calf MRA and the large field-of-view MRA has not been scientifically evaluated. Therefore the aim of this study was to evaluate if the quality of the combined large field-of-view MRA (CTM MR angiography) and time-resolved MRA with stochastic interleaved trajectories (TWIST MRA) depends on the order of acquisition of the two contrast-enhanced studies. Methods: In this retrospective study, 40 consecutive patients (mean age 68.1 ± 8.7 years, 29 male/11 female) who had undergone an MR angiographic protocol that consisted of CTM-MRA (TR/TE, 2.4/1.0 ms; 21° flip angle; isotropic resolution 1.2 mm; gadolinium dose, 0.07 mmol/kg) and TWIST-MRA (TR/TE 2.8/1.1; 20° flip angle; isotropic resolution 1.1 mm; temporal resolution 5.5 s, gadolinium dose, 0.03 mmol/kg), were included. In the first group (group 1) TWIST-MRA of the calf station was performed 1–2 min after CTM-MRA. In the second group (group 2) CTM-MRA was performed 1–2 min after TWIST-MRA of the calf station. The image quality of CTM-MRA and TWIST-MRA were evaluated by 2 two independent radiologists in consensus according to a 4-point Likert-like rating scale assessing overall image quality on a segmental basis. Venous overlay was assessed per examination. Results: In the CTM-MRA, 1360 segments were included in the assessment of image quality. CTM-MRA was diagnostic in 95% (1289/1360) of segments. There was a significant difference (p < 0.0001) between both groups with regard to the number of segments rated as excellent and moderate. The image quality was rated as excellent in group 1 in 80% (514/640 segments) and in group 2 in 67% (432/649), respectively (p < 0.0001). In contrast, the image quality was rated as moderate in the first group in 5% (33/640) and in the second group in 19% (121/649) respectively (p < 0.0001). The venous overlay was disturbing in 10% in group 1 and 20% in group 2 (p = n.s.). Conclusion: If a combined hybrid MRA approach with large field-of-view and time-resolved MRA is acquired the large field-of-view MRA should be acquired first in order for optimal image quality
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2011.12.003Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2011.12.003;
- PII
- S0720-048X(11)00834-5;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 10
- Journal Page Range
- p. 2754-2758
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Cuba
- INIS RN
- 45043878
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; CALVES; DOSES; FEMALES; GADOLINIUM; IMAGES; MALES; PATIENTS; STOCHASTIC PROCESSES; TRAJECTORIES
- Descriptors DEC
- ANIMALS; BODY; CARDIOVASCULAR SYSTEM; CATTLE; DIAGNOSTIC TECHNIQUES; DOMESTIC ANIMALS; ELEMENTS; MAMMALS; MEDICINE; METALS; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RARE EARTHS; RUMINANTS; VERTEBRATES
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.