Published 1998
| Version v1
Book
Design and construction of AC loss measuring system
Description
An experimental system for measuring AC losses is designed and being constructed. The AC losses will be measured by isothermal calorimetric method. A cryogenic system has been established and worked well. The calorimeter is designed to be removable and the tested sample can be replaced during the experiment. The different kind ac-losses of short samples is calculated by a simple code. The result is a basis for choosing a suitable gas flow-meter. (author)
Additional details
Publishing Information
- Publisher
- Association Euratom-CEA Cadarache
- Imprint Place
- Saint-Paul-Lez-Durance (France)
- Imprint Title
- Fusion technology 1998
- Imprint Pagination
- (v.1-2) 1744 p.
- Journal Page Range
- p. 787-789
Conference
- Title
- 20. symposium on fusion technology
- Dates
- 7-11 Sep 1998
- Place
- Marseille (France)
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 31008046
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AC LOSSES; CALORIMETERS; CRITICAL CURRENT; MEASURING METHODS; SUPERCONDUCTING CABLES
- Descriptors DEC
- CABLES; CONDUCTOR DEVICES; CURRENTS; ELECTRIC CABLES; ELECTRIC CURRENTS; ELECTRICAL EQUIPMENT; ENERGY LOSSES; EQUIPMENT; MEASURING INSTRUMENTS
Optional Information
- Notes
- 2 refs.