Published November 2000 | Version v1
Journal article

Absorbed dose distributions in a tissue-equivalent absorber for Bremsstrahlung produced at the beamlines of the European Synchrotron Radiation Facility

Description

The absorbed-dose distributions for Bremsstrahlung, incident on a tissue-equivalent phantom, were measured with LiF : Mg,Ti thermoluminescent dosimeters at two insertion device beamlines of the European Synchrotron Radiation Facility (ESRF). The measurements were carried out for two different electron beam energies of 4 and 6 GeV. The corresponding Bremsstrahlung spectra and power were measured using a high-resolution lead glass total absorption calorimeter. The results are compared with similar measurements carried out at other facilities. The normalized Bremsstrahlung absorbed dose in a cross-sectional area of 100 mm2, at a depth of 150 mm of the phantom, was measured as 6.1 and 3.6 kGy h-1 W-1 for the corresponding Bremsstrahlung spectra of 4 and 6 GeV.

Additional details

Identifiers

PII
S0969806X0000311X;

Publishing Information

Journal Title
Radiation Physics and Chemistry (1993)
Journal Volume
59
Journal Issue
5-6
Journal Page Range
p. 459-466
ISSN
0969-806X
CODEN
RPCHDM

Optional Information

Copyright
Copyright (c) 2000 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.
Notes
This record replaces 34052395