Published 1996 | Version v1
Book

Comparative study of the worth of full length shim rods versus spilt rods

  • 1. Nuclear Power Corporation of India Ltd., Mumbai (India). Reactor Safety Analysis Group
  • 2. Bhabha Atomic Research Centre, Bombay (India). Theoretical Physics Div.

Description

Future reactors from Kaiga-1 and 2 are proposed to have a single full length shim rod (SR) instead of two spilt rods at each location as in Narora Atomic Power Station (NAPS) and Kakrapar Atomic Power Station (KAPS). Options for using pure SS or cadmium sandwiched stainless steel (SS-Cd-SS) as neutron absorbing material for SRs are also being proposed as alternative to the presently used borated stainless steel. This paper presents the salient features associated with the full length shim rods. (author). 1 ref., 1 tab., 2 figs

Part of:
National conference on radiation shielding and protection (RASP-96): Proceedings

Additional details

Publishing Information

Publisher
Allied Publishers Limited.
Imprint Place
New Delhi (India)
ISBN
81-7023-541-3
Imprint Title
National conference on radiation shielding and protection (RASP-96): Proceedings
Imprint Pagination
321 p.
Journal Page Range
p. 109-112.

Conference

Title
national conference on radiation shielding and protection.
Acronym
RASP-96
Dates
26-28 Jun 1996.
Place
Kalpakkam (India).

Optional Information