Published March 1997
| Version v1
Journal article
The BaBar Silicon Vertex Tracker
Description
The Silicon Vertex Tracker (SVT) of the BaBar detector is presented. The specifications and the requirements of the detector and of the electronic readout are briefly discussed. (orig.)
Additional details
Publishing Information
- Journal Title
- Nuclear Physics. B, Proceedings Supplements
- Journal Volume
- 54B
- Journal Page Range
- p. 49-56.
- ISSN
- 0920-5632
- CODEN
- NPBSE7
Conference
- Title
- 6. topical seminar on experimental apparatus for particle physics and astrophysics.
- Dates
- 20-24 May 1996.
- Place
- San Miniato (Italy).
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 28050414
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DATA ACQUISITION SYSTEMS; INTEGRATED CIRCUITS; PARTICLE TRACKS; PHYSICAL RADIATION EFFECTS; POSITION SENSITIVE DETECTORS; POWER SUPPLIES; READOUT SYSTEMS; RELIABILITY; SI SEMICONDUCTOR DETECTORS; SPATIAL RESOLUTION
- Descriptors DEC
- ELECTRONIC CIRCUITS; ELECTRONIC EQUIPMENT; EQUIPMENT; MEASURING INSTRUMENTS; RADIATION DETECTORS; RADIATION EFFECTS; RESOLUTION; SEMICONDUCTOR DETECTORS
Optional Information
- Collaborations
- BABAR Collaboration.