A multistage, 4 MV, low jitter, command triggered gas switch is being developed for use on large pulse power devices. Experiments to date have shown that the performance and operational life of the switch are severely limited by mechanical and electrical failure of the insulating housing. Estimates of the internal overpressure produced during switch closure have been made which indicate the severity of the blast containment problem; this information has led to the development of a mechanically stronger switch design. Surface analyses performed on both switch electrode and insulator surfaces were used to investigate observed electrical failure of the insulators. A layer of closely spaced metal particles were found imbedded in the insulator walls

Additional details

Publishing Information

Imprint Title
2nd IEEE international pulsed power conference. Digest of technical papers
Journal Page Range
p. 450-453.
Report number
CONF-790622--

Conference

Title
2. international pulsed power conference.
Dates
12-14 Jun 1979.
Place
Lubbock, TX (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16073162
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FAILURES; GASES; POWER SUPPLIES; SWITCHES
Descriptors DEC
ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; EQUIPMENT; FLUIDS