First clinical investigation of a 4D maximum likelihood reconstruction for 4D PET-based treatment verification in ion beam therapy

  • 1. Department of Radiation Oncology, Heidelberg University Hospital (Germany)
  • 2. Department of Radiation Oncology, Klinikum der Ludwig-Maximilians-Universität München (Germany)
  • 3. Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich) (Germany)
  • 4. Medicine and Surgery Department – Tecnomed Foundation, University of Milano-Bicocca (Italy)
  • 5. Department of Radiation Oncology, European Institute of Oncology, Milan (Italy)
  • 6. Heidelberg Ion Beam Therapy Center, Heidelberg University Hospital (Germany)
  • 7. Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano (Italy)
  • 8. Bioengineering Unit, National Center for Oncologic Hadrontherapy, CNAO Foundation, Pavia (Italy)

Description

Background and purpose: In clinical applications of Positron Emission Tomography (PET)-based treatment verification in ion beam therapy (PT-PET), detection and interpretation of inconsistencies between Measured PET and Expected PET are mostly limited by Measured PET noise, due to low count statistics, and by Expected PET bias, especially due to inaccurate washout modelling in off-line implementations. In this work, a recently proposed 4D Maximum Likelihood (ML) reconstruction algorithm which considers Measured PET and Expected PET as two different motion phases of a 4D dataset is assessed on clinical 4D PET-CT datasets acquired after carbon ion therapy. Material and methods: The 4D ML reconstruction algorithm estimates: (1) Measured PET of enhanced image quality with respect to the conventional Measured PET, thanks to the exploitation of Expected PET; (2) the deformation field mapping the Expected PET onto the Measured PET as a measure of the occurred displacements. Results: Results demonstrate the desired sensitivity to inconsistencies due to breathing motion and/or setup modification, robustness to noise in different count statistics scenarios, but a limited sensitivity to Expected PET washout inaccuracy. Conclusions: The 4D ML reconstruction algorithm supports clinical 4D PT-PET in ion beam therapy. The limited sensitivity to washout inaccuracy can be detected and potentially overcome.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2017.04.018

Additional details

Identifiers

DOI
10.1016/j.radonc.2017.04.018;
PII
S0167-8140(17)30159-7;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
123
Journal Issue
3
Journal Page Range
p. 339-345
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49072488
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ION BEAMS; POSITRON COMPUTED TOMOGRAPHY; RADIOSENSITIVITY; VERIFICATION
Descriptors DEC
BEAMS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; SENSITIVITY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.