In situ measurement of residual plutonium
Description
Nondestructive assay techniques were developed and implemented to permit the measurement of residual plutonium in glove boxes, conveyors, and tanks in areas of varying background using both gamma and neutron portable detection equipment. The gamma detector was a 2 x 2 inch sodium iodide detector collimated to view a well defined area. The neutron detector consisted of 3He tubes in a polyethylene case with a small amount of directionality. Application of the described techniques to equipment prior to removal has shortened the clean-up time by identifying the locations of recoverable quantities. The agreement between assigned values and recovered plutonium has been within 16 percent for quantities ranging from several grams up to kilogram levels
Availability note (English)
MF available from INIS under the Report Number.Files
8289133.pdf
Files
(1.0 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:90928e913f6bcc23e742900636800427
|
1.0 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 21 p.
- Report number
- ARH-SA--248
Conference
- Title
- 17. annual meeting of the institute of nuclear materials management.
- Dates
- 23 Jun 1976.
- Place
- Seattle, Washington, United States of America (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8289133
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- GLOVEBOXES; NONDESTRUCTIVE ANALYSIS; PLUTONIUM; RADIOMETRIC ANALYSIS; TANKS
- Descriptors DEC
- ACTINIDES; CHEMICAL ANALYSIS; CONTAINERS; ELEMENTS; LABORATORY EQUIPMENT; METALS; QUANTITATIVE CHEMICAL ANALYSIS; TRANSURANIUM ELEMENTS
Optional Information
- Notes
- Available from NTIS. $3.50.
- Secondary number(s)
- CONF-760615--12.