Published June 30, 1976 | Version v1
Report Open

In situ measurement of residual plutonium

Description

Nondestructive assay techniques were developed and implemented to permit the measurement of residual plutonium in glove boxes, conveyors, and tanks in areas of varying background using both gamma and neutron portable detection equipment. The gamma detector was a 2 x 2 inch sodium iodide detector collimated to view a well defined area. The neutron detector consisted of 3He tubes in a polyethylene case with a small amount of directionality. Application of the described techniques to equipment prior to removal has shortened the clean-up time by identifying the locations of recoverable quantities. The agreement between assigned values and recovered plutonium has been within 16 percent for quantities ranging from several grams up to kilogram levels

Availability note (English)

MF available from INIS under the Report Number.

Files

8289133.pdf

Files (1.0 MB)

Name Size Download all
md5:90928e913f6bcc23e742900636800427
1.0 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
21 p.
Report number
ARH-SA--248

Conference

Title
17. annual meeting of the institute of nuclear materials management.
Dates
23 Jun 1976.
Place
Seattle, Washington, United States of America (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
8289133
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
GLOVEBOXES; NONDESTRUCTIVE ANALYSIS; PLUTONIUM; RADIOMETRIC ANALYSIS; TANKS
Descriptors DEC
ACTINIDES; CHEMICAL ANALYSIS; CONTAINERS; ELEMENTS; LABORATORY EQUIPMENT; METALS; QUANTITATIVE CHEMICAL ANALYSIS; TRANSURANIUM ELEMENTS

Optional Information

Notes
Available from NTIS. $3.50.
Secondary number(s)
CONF-760615--12.