Published November 1, 2018 | Version v1
Journal article

A sparkless resistive glass correction electrode for the spherical proportional counter

  • 1. IRFU, CEA, Université Paris-Saclay, Gif-sur-Yvette, F-91191 (France)
  • 2. School of Physics and Astronomy, University of Birmingham, Birmingham, B15 2TT (United Kingdom)
  • 3. Department of Nuclear and Elementary Particle Physics, Aristotle University of Thessaloniki, University Campus, Thessaloniki, 54124 (Greece)

Description

A new anode support structure for the spherical proportional counter is presented that incorporates a resistive correction electrode made of glass. This electrode improves the electric field homogeneity versus angle, while suppressing the probability and intensity of sparks compared to non-resistive alternatives. The configuration of the correction electrode was optimised with simulations. Such support structures have been constructed and measurements have demonstrated homogeneous response of the detector and operational stability. A measurement of the resistivity of the glass used is also presented.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/13/11/P11006

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
13
Journal Issue
11
Journal Page Range
p. P11006
ISSN
1748-0221

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
51051180
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
COMPARATIVE EVALUATIONS; COMPUTERIZED SIMULATION; ELECTRIC FIELDS; GLASS; PROPORTIONAL COUNTERS; SPHERICAL CONFIGURATION; STABILITY
Descriptors DEC
CONFIGURATION; EVALUATION; MEASURING INSTRUMENTS; RADIATION DETECTORS; SIMULATION