Published January 2016 | Version v1
Journal article

Automated production of [18F]VAT suitable for clinical PET study of vesicular acetylcholine transporter

Description

Automated production of a promising radiopharmaceutical (−)−(1−(8−(2−[18F]fluoroethoxy) -3-hydroxy-1,2,3,4-tetrahydronaphthalen-2-yl)-piperidin-4-yl) (4-fluorophenyl) methanone ([18F]VAT) for the vesicular acetylcholine transporter(VAChT) was achieved using a two-step procedure in a current Good Manufacturing Practices fashion. The production of [18F]VAT was accomplished in approximately 140 min, with radiochemical yield of ~15.0% (decay corrected), specific activity>111 GBq/µmol, radiochemical purity>99% and mass of VAT ~3.4 μg/batch (n>10). The radiopharmaceutical product meets all quality control criteria for human use, and is suitable for clinical PET studies of VAChT. - Highlights: • Automated production of a novel PET tracer [18F]VAT for VAChT was established using a two-step procedure. • [18F]VAT were synthesized with high radiochemical yield, good reproducibility and high product quality. • The radiopharmaceutical product of [18F]VAT is suitable for clinical PET studies.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2015.09.010

Additional details

Identifiers

DOI
10.1016/j.apradiso.2015.09.010;
PII
S0969-8043(15)30193-7;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
107
Journal Page Range
p. 40-46
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.