Published February 1975 | Version v1
Report Open

A computer program for peak identification in secondary ion mass spectra

  • 1. Oesterreichische Studiengesellschaft fuer Atomenergie G.m.b.H., Seibersdorf. Physik-Inst.

Description

A computer program is described which performs quantitative assignment of elemental and molecular ion currents to the mass peaks in a secondary ion mass spectrum. The program relies on natural isotopic abundances for the identification of atomic and molecular ions. Isolemental clusters, oxides, dioxides, oxyhydrides and hybride molecules can be identified. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

9363927.pdf

Files (646.5 kB)

Name Size Download all
md5:b5b6e70db84d0b167b8e1464928d8912
646.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
56 p.
Report number
SGAE--2421

INIS

Country of Publication
Austria
Country of Input or Organization
Austria
INIS RN
9363927
Subject category
S74: ATOMIC AND MOLECULAR PHYSICS;
Descriptors DEI
ATOMIC IONS; ION EMISSION; MASS SPECTRA; MOLECULAR IONS; PEAKS; RADIOMETRIC ANALYSIS; S CODES; SECONDARY EMISSION
Descriptors DEC
CHARGED PARTICLES; CHEMICAL ANALYSIS; COMPUTER CODES; EMISSION; IONS; QUANTITATIVE CHEMICAL ANALYSIS; SPECTRA

Optional Information

Notes
In abridged form already published in Vacuum 25(1975), No. 9/10, p. 409-413.
Secondary number(s)