Published August 2010 | Version v1
Journal article

Different approaches for quantifying ventilation distribution and lung tissue properties by functional EIT

  • 1. Department of Anaesthesiology, Emergency and Intensive Care Medicine, University Medical Center Göttingen, Robert-Koch-Str. 40, D-37075 Göttingen (Germany)

Description

We investigated five different methods which can be applied to quantitatively construct functional tomograms of the lungs. The focus was on the sensitivity of functional tomograms to errors in acquired data. To quantify this sensitivity, theoretical, error-free data sets of well-known properties were artificially generated based on a 'living thorax model'. Physiological time courses and a typical distribution of errors caused by a typical Goe-MF II EIT system were used for the calculations which encompassed a range up to 50 times greater than the initial error level (4 µVrms max–400 µVrms max). Additionally, low-pass filtering and principal component analysis (PCA) were used to quantify the effect of preprocessing the raw data. The results demonstrate that all methods based on fitting the local to the global time course were superior to the common functional tomograms utilizing standard deviation or maximum and minimum detection. Ventilation distribution was best quantified by the so-called VT methods. Filling capacity—a lung tissue property—was least dependent on increasing error levels. The errors introduced by filtering are significant with respect to a quantitative analysis of ventilation distribution. A preprocessing of raw data by applying a PCA performed well on the data sets which had been constructed but were, nonetheless, realistic. This approach appears to be highly promising for application on real data which is known to be erroneous

Availability note (English)

Available from http://dx.doi.org/10.1088/0967-3334/31/8/S06

Additional details

Identifiers

DOI
10.1088/0967-3334/31/8/S06;
PII
S0967-3334(10)39084-8;

Publishing Information

Journal Title
Physiological Measurement (Print)
Journal Volume
31
Journal Issue
8
Journal Page Range
p. S73-S84
ISSN
0967-3334

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47046412
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
Descriptors DEI
ANIMAL TISSUES; CHEST; DISTRIBUTION; ERRORS; FILTERS; LUNGS; SENSITIVITY; TOMOGRAPHY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; ORGANS; RESPIRATORY SYSTEM