Published February 1983 | Version v1
Report Open

Determination of the thoron daughter working level by a one gross alpha-count

Description

A study has been done on the determination of the thoron daughter Working Level, WL(Tn), by a one gross α-count. The relationship between the gross α-count rate per unit of volume of air sampled and WL(Tn), denoted the F-factor, has been investigated as a function of sampling time, elapsed time from the end of the sampling period, i.e., waiting time, and the thoron daughter disequilibrium ratio [ThC]/[ThB]. It has been found that F depends on both the waiting time and [ThC]/[ThB]. If α-count measurements are made at least 300 min after the end of sampling, F changes by less than 10 percent over the full range of theoretical values of [ThC]/[ThB], i.e., from 0 to 1. The F-factor is independent of [ThC]/[ThB] at approximately 215 min after the end of sampling. This feature can be used to determine WL(Tn) with higher accuracy and at least 1.5 hr earlier than is commonly done using other one gross α-count methods reported in the literature

Availability note (English)

MF available from INIS under the Report Number.

Files

16054000.pdf

Files (344.7 kB)

Name Size Download all
md5:07d4a2f3fc1a132edf8d35be357ba446
344.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
23 p.
Report number
MRP/MSL--83-13(TR)

INIS