Myocardial perfusion (MP) PET imaging plays an important role in risk assessment and stratification of patients with coronary artery disease. In this work, we developed an anatomy-assisted maximum a posteriori (MAP) reconstruction method incorporating a wavelet-based joint entropy (WJE) prior for MP PET imaging. Using the XCAT phantom, we first simulated three MP PET datasets, one with normal perfusion and the other two with non-transmural and transmural regionally reduced perfusion of the left ventricular myocardium. We then simulated MP PET datasets of the three cases with respiratory and cardiac (RC) motion to represent realistic clinical situations. Moreover, two MR image datasets of the same subjects without and with RC motion were simulated without the perfusion defect correspondence. Using the simulated data, the proposed method was evaluated quantitatively in terms of noise–contrast tradeoff, and compared with the post-smoothed maximum-likelihood and the conventional MAP methods. The detectability of perfusion defects with various myocardial coverage was also evaluated through receiver operating characteristic analysis using the channelized Hotelling observer. The results demonstrated that the WJE-MAP method improved the noise–contrast tradeoff, leading to significantly enhanced defect detectability over the other two methods in the non-transmural defects, while maintaining comparable performance in the transmural defect. In addition to the simulation study, the proposed method was further evaluated on the acquired PET/MRI data of a Jaszczak phantom with cold rods. Compared with the other two methods, the WJE-MAP method improved the tradeoff between noise and contrast in the smaller rods, thereby indicating its clinical potential for improving defect detectability in MP PET/MR imaging. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-6560/aad8f9Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 63
- Journal Issue
- 17
- Journal Page Range
- [15 p.]
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52003078
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- DATASETS; DEFECTS; ENTROPY; JOINTS; MAXIMUM-LIKELIHOOD FIT; NMR IMAGING; POSITRON COMPUTED TOMOGRAPHY; RISK ASSESSMENT; SIMULATION
- Descriptors DEC
- COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DOCUMENT TYPES; EMISSION COMPUTED TOMOGRAPHY; MATHEMATICAL SOLUTIONS; NUMERICAL SOLUTION; PHYSICAL PROPERTIES; THERMODYNAMIC PROPERTIES; TOMOGRAPHY