Published 1985 | Version v1
Book

Borated concrete for ZPPR fuel storage

Creators

  • 1. Argonne National Lab., Idaho Falls, ID

Description

Fuel handling at the Zero Power Plutonium Reactor (ZPPR) led to two requirements for storage of ZPPR fuel: a low neutron multiplication and shielded storage to minimize personnel doses. Boron-poisoned concrete was chosen as the storage medium with boron frit as the poisoning agent. The calculated effects of water content and boron concentration led to specifying a concrete with a water content that was higher than ordinary concrete. The finite size of the boron frit particles caused concern about reduced effectiveness due to self-shielding. The self-shielding was evaluated using optical path lengths for spheres and tabulated self-shielding for slabs

Additional details

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (USA)
ISBN
0-89448-119-3
Imprint Title
Proceedings of a topical meeting on criticality safety in the storage of fissile material
Journal Page Range
p. 170.

Conference

Title
Topical meeting on criticality safety and the storage of fissile material.
Dates
9-12 Sep 1985.
Place
Jackson, WY (USA).