Published December 1987 | Version v1
Journal article

Radial dose distribution for 18.3 MeV/n alpha beams in tissue-equivalent gas

  • 1. National Institute of Radiological Sciences, Chiba, Japan

Description

Experimental measurements of the radial restricted linear energy transfer (LETr) for alpha beams of 18.3 MeV/n in tissue-equivalent gas were presented. The radial dose distribution for the alpha beam was deduced from the restricted LET measurements. A differential W value for the alpha particle in the tissue-equivalent gas was also deduced. The result for the differential W value was 29.0 +/- 0.9 eV/ion pair. The radial dose varied according to an inverse-square function with distance from the track center for radii larger than 0.026 micron. The maximum extension of the track, the penumbra radius, as 2.73 +/- 1.67 microns, which was less than predicted by calculations (7-9 microns)

Additional details

Publishing Information

Journal Title
Radiat. Res.
Journal Volume
112
Journal Issue
3
Series
Radiat. Res.
Journal Page Range
426-435
ISSN
0033-7587
CODEN
RAREA

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19050595
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
ALPHA BEAMS; ALPHA PARTICLES; ENERGY TRANSFER; GASES; RADIATION DOSE DISTRIBUTIONS; TISSUE-EQUIVALENT MATERIALS
Descriptors DEC
BEAMS; CHARGED PARTICLES; FLUIDS; HELIUM IONS; HELIUM 4 BEAMS; ION BEAMS; IONIZING RADIATIONS; IONS; MATERIALS; RADIATIONS