Published December 1987
| Version v1
Journal article
Radial dose distribution for 18.3 MeV/n alpha beams in tissue-equivalent gas
Description
Experimental measurements of the radial restricted linear energy transfer (LETr) for alpha beams of 18.3 MeV/n in tissue-equivalent gas were presented. The radial dose distribution for the alpha beam was deduced from the restricted LET measurements. A differential W value for the alpha particle in the tissue-equivalent gas was also deduced. The result for the differential W value was 29.0 +/- 0.9 eV/ion pair. The radial dose varied according to an inverse-square function with distance from the track center for radii larger than 0.026 micron. The maximum extension of the track, the penumbra radius, as 2.73 +/- 1.67 microns, which was less than predicted by calculations (7-9 microns)
Additional details
Publishing Information
- Journal Title
- Radiat. Res.
- Journal Volume
- 112
- Journal Issue
- 3
- Series
- Radiat. Res.
- Journal Page Range
- 426-435
- ISSN
- 0033-7587
- CODEN
- RAREA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19050595
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ALPHA BEAMS; ALPHA PARTICLES; ENERGY TRANSFER; GASES; RADIATION DOSE DISTRIBUTIONS; TISSUE-EQUIVALENT MATERIALS
- Descriptors DEC
- BEAMS; CHARGED PARTICLES; FLUIDS; HELIUM IONS; HELIUM 4 BEAMS; ION BEAMS; IONIZING RADIATIONS; IONS; MATERIALS; RADIATIONS