Published June 1975
| Version v1
Report
Restricted
ECCS evaluation of B and W's 177-FA raised-loop NSS
Description
The effectivness of the ECCS for B and W's 177-FA plants with raised loop design has been evaluated and shown to meet all requirements of 10 CFR 50.46. The results of various sensitivity studies, a spectrum of breaks, and an analysis to determine the linear heat rates allowable under 10 CFR 50.46 are presented. 13 references. (U.S.)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Additional titles
- Augmented title (English)
- PWR type reactors
Publishing Information
- Imprint Pagination
- 184 p.
- Report number
- BAW--10105
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 6209911
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ECCS; HEAT TRANSFER; HYDRAULICS; LIQUID FLOW; LOSS OF COOLANT; PERFORMANCE; PRESSURE GRADIENTS; PWR TYPE REACTORS; REACTOR SAFETY; SPATIAL DISTRIBUTION
- Descriptors DEC
- ACCIDENTS; DISTRIBUTION; ENERGY TRANSFER; FLUID FLOW; REACTOR ACCIDENTS; REACTOR PROTECTION SYSTEMS; REACTORS; SAFETY; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- Babcock and Wilcox, Lynchburg, VA.