Published May 1981 | Version v1
Book

Investigations on denting phenomenon in monel tubes

  • 1. Bhabha Atomic Research Centre, Bombay (India). Metallurgy Div.

Description

Denting phenomenon as experienced in PWR steam generators has been investigated in the laboratory of Monel-400 tubes and C-steel baffles combination. Isothermal corrosion tests have been carried out by exposing capsules, containing a crevice between Monel-400 tubes and C-steel plugs, in plausible corrodents at 3000C. Results indicated that the denting phenomenon is strongly influenced by the chloride content in the solution. In addition, it is a time dependent process. Stress exerted on the tubes by the growth of corrosion product on the outside surface of C-steel plugs are enough to deform the Monel tubes. The results have been discussed on the basis of accelerated corrosion of C-steel by hydrolyzable metal chlorides. (author)

Additional details

Additional titles

Augmented title (English)
denting, tube and tube support interaction

Publishing Information

Publisher
Department of Atomic Energy.
Imprint Place
Bombay (India)
Imprint Title
Proceedings of the nuclear chemistry and radiochemistry symposium (held at) Waltair, February 25-28, 1980
Imprint Pagination
681 p.
Journal Page Range
p. 441-443.

Conference

Title
Nuclear chemistry and radiochemistry symposium.
Dates
25-28 Feb 1980.
Place