Vacuum system design and tritium inventory for the TFTR charge exchange diagnostic
Description
The charge exchange diagnostic for the TFTR is comprised of two analyzer systems which contain a total of twenty independent mass/energy analyzers and one diagnostic neutral beam tentatively rated at 80 keV, 15 A. The associated vacuum systems were analyzed using the Vacuum System Transient Simulator (VSTS) computer program which models the transient transport of multi-gas species through complex networks of ducts, valves, traps, vacuum pumps, and other related vacuum system components. In addition to providing improved design performance at reduced cost, the analysis yields estimates for the exchange of tritium from the torus to the diagnostic components and of the diagnostic working gases to the torus
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01.Files
10492793.pdf
Files
(1.3 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:ecf44424e9e113f30ffe682f31f45efd
|
1.3 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 50 p.
- Report number
- PPPL--1551
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10492793
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CHARGE EXCHANGE; INVENTORIES; MASS SPECTROMETERS; NEUTRAL ATOM BEAM INJECTION; PLASMA DIAGNOSTICS; TFTR DEVICE; TRITIUM; VACUUM SYSTEMS
- Descriptors DEC
- BEAM INJECTION; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CLOSED PLASMA DEVICES; HYDROGEN ISOTOPES; ISOTOPES; LIGHT NUCLEI; MEASURING INSTRUMENTS; NUCLEI; ODD-EVEN NUCLEI; RADIOISOTOPES; SPECTROMETERS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES; YEARS LIVING RADIOISOTOPES