Published August 1, 2003 | Version v1
Journal article

Experimental results on RPC neutron sensitivity

Description

RPC neutron sensitivity has been studied during two tests done with different neutrons energies. In the first test, neutrons from spontaneous fission events of 252Cf were used (average energy 2 MeV); while in the second test neutrons were produced using a 50 MeV deuteron beam on a 1 cm thick beryllium target (average energy 20 MeV). Preliminary results show that the neutron sensitivity in double gap mode is (0.52±0.03)x10-3 at about 2 MeV and (5.3±0.5)x10-3 at about 20 MeV

Additional details

Identifiers

PII
S0168900203012816;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
508
Journal Issue
1-2
Journal Page Range
p. 79-82
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
6. international workshop on resistive plate chambers and related detectors
Dates
26-27 Nov 2001
Place
Coimbra (Portugal)

Optional Information

Copyright
Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.