Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT. A feasibility study in patients
Creators
- 1. Department of Radiology, Mayo Clinic, Rochester, MN (United States)
- 2. Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN (United States)
Description
To evaluate ultra-high-resolution (UHR) imaging of large joints using an investigational photon-counting detector (PCD) CT. Patients undergoing clinical shoulder or pelvis energy-integrating-detector (EID) CT exam were scanned using the UHR mode of the PCD-CT system. Axial EID-CT images (1-mm sections) and PCD-CT images (0.6-mm sections) were reconstructed using Br62/Br64 and Br76 kernels, respectively. Two musculoskeletal radiologists rated visualization of anatomic structures using a 5-point Likert scale. Wilcoxon rank-sum test was used for statistical analysis of reader scores, and paired t-test was used for comparing bone CT numbers and image noise from PCD-CT and EID-CT. Thirty-two patients (17 shoulders and 15 pelvis) were prospectively recruited for this feasibility study. Mean age for shoulder exams was 67.3 ± 15.5 years (11 females) and 47.2 ± 15.8 years (11 females) for pelvis exams. The mean volume CT dose index was lower on PCD-CT compared to that on EID-CT (shoulders: 18 mGy vs. 34 mGy, pelvis: 11.6 mGy vs. 16.7 mGy). PCD-CT was rated significantly better than EID-CT (p < 0.001) for anatomic-structure visualization. Trabecular delineation in shoulders (mean score = 4.24 ± 0.73) and femoroacetabular joint visualization in the pelvis (mean score = 3.67 ± 1.03) received the highest scores. PCD-CT demonstrated significant increase in bone CT number (p < 0.001) relative to EID-CT; no significant difference in image noise was found between PCD-CT and EID-CT. The evaluated PCD-CT system provided improved visualization of osseous structures in the shoulders and pelvises at a 31-47% lower radiation dose compared to EID-CT. A full field-of-view PCD-CT with 0.151 mm × 0.176 mm detector pixel size (isocenter) facilitates bilateral, high-resolution imaging of shoulders and pelvis. The evaluated investigational PCD-CT system was rated superior by two musculoskeletal radiologists for anatomic structure visualization in shoulders and pelvises despite a 31-47% lower radiation dose compared to EID-CT. PCD-CT demonstrated significantly higher bone CT number compared to EID-CT, while no significant difference in image noise was observed between PCD-CT and EID-CT despite a 31-47% dose reduction on PCD-CT.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-022-08925-xAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 32
- Journal Issue
- 10
- Journal Page Range
- p. 7079-7086
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 53110040
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARMS; BONE JOINTS; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; DATA COMPILATION; FEASIBILITY STUDIES; FEMUR; KERNELS; PELVIS; PHOTON COUNTING; RADIATION DOSES; SPATIAL RESOLUTION; X-RAY DETECTION
- Descriptors DEC
- BODY; DATA; DATA PROCESSING; DETECTION; DIAGNOSTIC TECHNIQUES; DOSES; EVALUATION; INFORMATION; LIMBS; ORGANS; PROCESSING; RADIATION DETECTION; RESOLUTION; SKELETON; TOMOGRAPHY