Radiation dose reduction in CT of the brain: can advanced noise filtering compensate for loss of image quality?

  • 1. Center for Medical Imaging and Physiology, Skaane Univ. Hospital, Lund (El Salvador)
  • 2. Dept. of Radiology, Lund Univ., Lund (El Salvador)
  • 3. Lund Univ. Bioimaging Center, Lund (El Salvador)

Description

Background: Computed tomography (CT) of the brain is performed with high local doses due to high demands on low contrast resolution. Advanced algorithms for noise reduction might be able to preserve critical image information when reducing radiation dose. Purpose: To evaluate the effect of advanced noise filtering on image quality in brain CT acquired with reduced radiation dose. Material and Methods: Thirty patients referred for non-enhanced CT of the brain were examined with two helical protocols: normal dose (ND, CTDIvol 57 mGy) and low dose (LD, CTDIvol 40 mGy) implying a 30% radiation dose reduction. Images from the LD examinations were also post processed with a noise reduction software with non-linear filters (SharpView CT), creating filtered low dose images (FLD) for each patient. The three image stacks for each patient were presented side by side in randomized order. Five radiologists, blinded for dose level and filtering, ranked these three axial image stacks (ND, LD, FLD) as best to poorest (1 to 3) regarding three image quality criteria. Measurements of mean Hounsfield units (HU) and standard deviation (SD) of the HU were calculated for large region of interest in the centrum semiovale as a measure for noise. Results: Ranking results in pooled data showed that the advanced noise filtering significantly improved the image quality in FLD as compared to LD images for all tested criteria. No significant differences in image quality were found between ND examinations and FLD. However, there was a notable inter-reader spread of the ranking. SD values were 15% higher for LD as compared to ND and FLD. Conclusion: The advanced noise filtering clearly improves image quality of CT examinations of the brain. This effect can be used to significantly lower radiation dose.

Availability note (English)

Available from DOI: http://dx.doi.org/10.1258/ar.2012.110629

Additional details

Identifiers

Publishing Information

Journal Title
Acta Radiologica (Online)
Journal Volume
53
Journal Issue
4
Journal Page Range
p. 468-472
ISSN
1600-0455

INIS

Country of Publication
Sweden
Country of Input or Organization
Sweden
INIS RN
43083178
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BRAIN; COMPUTERIZED TOMOGRAPHY; DOSE RATES; IMAGE PROCESSING; NOISE
Descriptors DEC
BODY; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; NERVOUS SYSTEM; ORGANS; PROCESSING; TOMOGRAPHY