Published April 1999 | Version v1
Journal article

Prediction of response to revascularization in patients with renal artery stenosis by Tc-99m-ethylene dicysteine captopril scintigraphy

  • 1. Hacettepe Univ., Ankara (Turkey). Medical School

Description

The aim of the present study was to assess the predictive value of captopril scintigraphy with the new renal agent 99mTc-ethylene dicysteine (99mTc-EC) for post-interventional improvement in blood pressure. Twelve patients who had persistently high blood pressure with previous demonstration of various degrees of renal artery lesion on angiography were included into the study. Baseline and captopril scintigraphies were performed on the same day at 4 hour intervals after the injection of 74 and 296 MBq of 99mTc-EC, respectively. All patients had percutaneous transluminal angioplasty (PTA), and improvement in blood pressure was evaluated 3-6 months after the intervention. 99mTc-EC captopril scintigraphy successfully predicted a positive or negative outcome in 11 of 12 patients. In one patient with captopril induced renal function deterioration, scintigraphy failed to predict post-interventional response. Our preliminary findings showed that 99mTc-EC captopril scintigraphy can be used to determine patients who will benefit from revascularization. (author)

Additional details

Publishing Information

Journal Title
Annals of Nuclear Medicine
Journal Volume
13
Journal Issue
2
Journal Page Range
p. 77-81
ISSN
0914-7187