Development of fast-response solved-tritium concentration diagnostics

Description

Status of continuous concentration sensing in lead-lithium and pressurized helium effluents is revisited. New sensor cap principles for tritium solute real-time/on-line measurements are discussed and proposed based on the use of double-wall/dual-side thin porous membrane and selective electrochemical sensing. General design features are provided together with anticipated predictable performances.