Improvement on resistive bolometer for measuring total soft X-ray yield generated by Z-pinches
Description
The resistive bolometer is an accurate, robust, spectrally broadband technique for measuring total soft X-ray yield. By replacing the pulsed voltage driver with a pulsed current driver and removing the series-wound resistance, the change of resistance between the ends of Ni-film can be measured directly, thus the measurement precision can be promoted effectively. The applicability of this improved resistive bolometer is expanded to all typical Z-pinch loads on 'Qiangguang-Ⅰ' facility. Data analysis shows that the uncertainty decreases from 49.0% to 19.6% in measuring X-ray yield generated by Al wire array Z-pinches. X-ray yield data from the resistive bolometer were compared with the ones from the X-ray power measure system. The ratios between them were between 0.87 and 1.04. (authors)
Additional details
Publishing Information
- Journal Title
- High Power Laser and Particle Beams
- Journal Volume
- 25
- Journal Issue
- 8
- Journal Page Range
- p. 2142-2146
- ISSN
- 1001-4322
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 47083823
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ACCELERATORS; ACCURACY; BOLOMETERS; CHINA; COMPARATIVE EVALUATIONS; DATA ANALYSIS; ELECTRIC POTENTIAL; ELECTRON BEAMS; FILMS; LINEAR Z PINCH DEVICES; NICKEL; PULSES; SOFT X RADIATION; WIRES; YIELDS
- Descriptors DEC
- ASIA; BEAMS; DATA PROCESSING; ELECTROMAGNETIC RADIATION; ELEMENTS; EVALUATION; IONIZING RADIATIONS; LEPTON BEAMS; LINEAR PINCH DEVICES; MEASURING INSTRUMENTS; METALS; OPEN PLASMA DEVICES; PARTICLE BEAMS; PINCH DEVICES; PROCESSING; RADIATIONS; THERMONUCLEAR DEVICES; TRANSITION ELEMENTS; X RADIATION
Optional Information
- Notes
- 5 figs., 1 tab., 15 refs.