Published 1988 | Version v1
Book

Routine neutron monitoring in the Federal Republic of Germany using a two-component albedo dosemeter system

  • 1. Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Hauptabteilung Sicherheit

Description

Energy dependence prevented a large scale routine application of albedo dosemeters in the past. This has been overcome by using location and facility dependent calibration factors. In the stray neutron fields of interest a large-scale routine monitoring has been recently realized with a two-component albedo dosemeter by classifying the variety of neutron fields in four types of applied without the need of knowing more details about the local situation such as the neutron energy spectrum, the shielding and the distance to the source. The calibration factors which may significantly vary with neutron energy in the four areas of application are transferable to other types of TLD systems using the two-component dosemeter capsule. In routine monitoring therefore is in general no need to perform field calibrations at the actual neutron facility of interest

Additional details

Publishing Information

Publisher
Pergamon Press.
Imprint Place
Sydney (Australia)
ISBN
008 03440 2 (v.1)
Imprint Title
Radiation protection practice
Imprint Pagination
3 v.
Journal Page Range
p. 265-268.

Conference

Title
7. international congress of the International Radiation Protection Association.
Dates
10-17 Apr 1988.
Place
Sydney (Australia).